SYSTEM 2000 GUARDRAIL IS UNIQUE

This revolutionary, British Board of Agrement Approved, guardrail has been specifically designed to provide permanent edge protection where regular access for maintenance and inspections is required.

The system's unique design provides permanent edge protection without the need to mechanically fix the system through the roofing membrane or building's structure.

This simple cantilever principle provides unrivalled strength, stability and safety and overcomes the problems associated with traditional systems such as having to drill and puncture the roof membrane which can lead to potential penetrative water damage and noise disturbance during installation.

Similarly, high levels of insulation included within warm deck and inverted flat roof designs often mean it is virtually impossible to fix through, as with traditional systems, without causing cold bridging. This may then cause interstitial condensation to form within the flat roof construction, causing the roof to deteriorate and eventually require replacement.

back to top


SYSTEM 2000 GUARDRAIL IS DURABLE

Safesite's guardrail components are supplied with a galvanised finish carried out to BS EN ISO 1461 : 1999 Hot Dip Galvanised Coatings Specification and Testing Methods, giving an average coating of between 65-85 microns. All locking screws are stainless-steel and are greased before fixing to ensure a maintenance free system.

back to top


SYSTEM 2000 GUARDRAIL IS SYSTEMISED

The system consists of galvanised tubing joined together using the "Safeclamp" method of connection. The vertical leg has been specifically designed so that the base foot can be raised or lowered allowing the system to be levelled during installation. In addition to this, the sliding base foot allows future re-roofing works to be completed without the need to dismantle the system. The base foot is connected to the low profile counter weight, giving the system its strength & stability.

back to top


SYSTEM 2000 GUARDRAIL IS VERSATILE

System 2000 has been specially designed to fit all shapes and sizes of flat roofs, even circular designs. The system can also cope with changes in levels, roof falls and difficult details such as ductwork passing over the roof edge and cable trays/plant mounted at the roof edge. The flexibility of the counter weight & Safeclamp design allows the system to be used on plant congested or complex detailed roofs.

back to top


SYSTEM 2000 GUARDRAIL MEMBRANE PROTECTION

The system is installed with fluted rubber matting bonded to the underside of all components in contact with the roof membrane. This protects the roof membrane from damage via heat transfer or direct contact with components. On warm deck roof construction specifications pedestrian tiles are recommended to be placed where base feet and counter weights are in contact with the roof membrane.

The fluted rubber also has the additional benefit of adding to the frictional resistance of the system to prevent any movement.

back to top


GUARDRAIL TESTING & CERTIFICATION

System 2000 has been fully assessed externally & awarded British Board of Agrement Approval. This independent certification is your guarantee that the system is designed, manufactured & installed to its full specification and tested correctly.

Testing was carried out by The British Standards Institute and the National Engineering Laboratory to the Health & Safety Executive Document SIR/15 :1987, MOAT No 43 1987. System 2000 is wind calculated to BS 6399 : Part 2 1997 Code of Practice for Wind Load. To ensure the system was tested in the most unfavourable conditions we included the Building Regulations interpretation of a flat roof design being up to 10 degree pitch and added a 25% safety factor to the more onerous wind calculations.

back to top


GUARDRAIL WIND CALCULATION

BS 6399 : Part 2 1997 Code of Practice for Wind Load. Wind loading is the most likely regular and demanding force a free standing roof guardrail will encounter during its lifetime. Safesite has developed a computerised programme to calculate the design of System 2000 to ensure compliance with the relevant wind loadings relating to the topography, height and location of the project throughout the UK.

back to top


OFFICIAL DOCUMENTATION

System 2000 complies with the following:-

  • British Board of Agrement Certificate No 95/3182
  • EN 13374: 2004 Temporary Edge Protection Systems-Product Specification Test Methods
  • BS 6399 : Part 2 1997 Code of Practice for Wind Load.
  • HSE/SIR 15 : 1987
  • MOAT No 43 : 1987
  • HSC Workplace (Health, Safety and Welfare) Regulation 13
  • HS/G 33 Health & Safety in Roofwork 1998
  • HSE Construction Sheet No 21 "Working on flat roofs protection against falls."
  • European Directives together with requirements of CDM Regulations.

Full documentation is available upon request.

back to top


SYSTEM 2000 GUARDRAIL AESTHETICS

The smooth lines of the standard galvanised finish can be further enhanced by the application of polyester powder coating to BS 6497 : 1984 Specification for Powder Organic Coatings, with bespoke colour produced to special order. System 2000 aesthetics can be improved by the addition of decorative design panels between the horizontal guardrails. These panels are welded between the horizontal rails during the fabrication process. Special designs can also be catered for within the System 2000 cantilevered principle, details on request. The concept of a decorative cantilevered system has been warmly welcomed by Planning Officers due to the improved aesthetics.

back to top


SYSTEM 2000 GUARDRAIL DISTRIBUTORS

System 2000 is available as a supply and installation service or component supply only. The system is available from Safesite directly or one of its licensed distributors within the UK & Overseas. For further inform on component supply please see Supply Only under the Services section.

back to top


SPECIALIST SYSTEMS

Safesite System 2000 has been specially adapted to provide roof edge protection on fragile roofs with the advantage of not fixing the system to the building's structure. This is a specialist service and each project is designed to the specific building's requirements. (See Mobile Valley Frame and Steel Fabrication sections).

back to top


SYSTEM RECERTIFICATION

System 2000 does not require annual maintenance, however there are occasions where third parties such as contractors and maintenance operators may tamper with the guardrail system while installing new equipment, modifying the system or connecting additional equipment to the guardrail.

Equipment may also need to be installed outside the area protected by the System 2000 Guardrail. If this is the case, maintenance engineers will be working in unprotected areas.

As a result of this and in line with Regulation 5 of the Workplace (Health, Safety and Welfare) Regulations which require a suitable system of maintenance for equipment, we recommend that an annual inspection and recertification of the guardrail is carried out in order to ensure that the guardrail continues to provide the level of protection for which it was originally designed.

Our experienced engineers are able to carry out a thorough recertification of the system as well as advise you or your client of any falls from height concerns that may have arisen since the original installation. This could include refurbishment programmes and/or extensions to the site or equipment installed.

back to top


HEAD OFFICE
NORTHERN OFFICE
Priestley Way
Crawley
West Sussex
RH10 2NT
Tel: 01293 529977
Fax: 01293 531166
info@safesite.co.uk

>>view map
15 Seymour Court
Manor Park
Runcorn
Cheshire
WA7 1SY
Tel: 01928 579988
Fax: 01928 579922
info@safesite.co.uk

>>view map

BBA
Quotation - Calculation Sheet

Click here to be taken to our S2000 Calculation Sheet

 

view

A premier installation for a premier hotel

Roof Edge Fabrications Ltd, Safesite Ltd's Scottish distributor, has recently completed the installation of Safesite's System 2000 cantilever guardrail system at the Copthorne Hotel, Aberdeen in order to enable safe access to the hotel's roof for maintenance purposes.

 

more

Cantilevered Edge Protection System

 

view

GRailA4_10
product name :GRailA4_10
AutoCad file
GRailA4_10.dwg
GRailA4_11
product name :GRailA4_11
AutoCad file
GRailA4_11.dwg
GRailA4_3
product name :GRailA4_3
AutoCad file
GRailA4_3.dwg
GRailA4_4
product name :GRailA4_4
AutoCad file
GRailA4_4.dwg
GRaila4_5
product name :GRaila4_5
AutoCad file
GRaila4_5.dwg
GRailA4_6
product name :GRailA4_6
AutoCad file
GRailA4_6.dwg
GRailA4_7
product name :GRailA4_7
AutoCad file
GRailA4_7.dwg
GRailA4_8
product name :GRailA4_8
AutoCad file
GRailA4_8.dwg
GRaila4_9
product name :GRaila4_9
AutoCad file
GRaila4_9.dwg
GRailWEXAMPLE1
product name :GRailWEXAMPLE1
AutoCad file
GRailWEXAMPLE1.dwg
GRaila4_1
product name :GRaila4_1
AutoCad file
GRaila4_1.dwg
GRail01
product name :GRail01
AutoCad file
GRail01.dwg
GRail01a_sec
product name :GRail01a_sec
AutoCad file
GRail01a_sec.dwg

 

view

The following is a list of components used for the Cantilevered edge protection system

Base Foot
Cantilever Tube
Counter Weight
Intermediate Base Foot
Support Leg
Main Rail Tube
Cross Over Clamp
On Line Connector
90º Elbow
T-connector
Adjustable Elbow
Wall/ladder Clamp
Wall Fixing
L Bar
Link Tube
Plastic Cap

 

view